Appendix C RAID Controller Considerations

RAID Controller Cabling

Example 1—One Nonexpander and One RAID Controller with Eight Drives

Figure C-1shows an example of a server that is using one RAID controller in PCIe slot 3 and a nonexpander transition card to control eight drives in the modular drive bay.

Two RAID cables are required (1 UCSC-CABLE-S and 1 UCSC-CABLE-L).

The blue line is a 0.8m cable (UCSC-CABLE-S) from the RAID controller SAS 0 connector to the nonexpander connector for PORT 1–4.

The red line is a 1m cable (UCSC-CABLE-L) from the RAID controller SAS 1 connector to the nonexpander connector for PORT 5–8.

The green line is the cable from the RAID controller to the SCPM backup unit.

Figure C-1 RAID Controller Cabling Guidelines, Nonexpander Transition Card

 

1

2

3

 

 

 

334371

1

Nonexpander transition card

3 RAID controller card in PCIe slot 3

 

(shown with fan tray removed)

 

 

2

SCPM backup unit

 

 

 

(mounted to tray on air baffle)

 

 

Cisco UCS C420 Server Installation and Service Guide

 

OL-27640-01

C-3

 

Page 103
Image 103
Cisco Systems UCS C420 manual 334371