Appendix C RAID Controller Considerations

RAID Controller Cabling

Example 3—Two Expanders and One RAID Controller with Sixteen Drives

Figure C-3shows an example of a server that is using one RAID controller in PCIe slot 3 and two expander transition cards to control eight drives in each of the two modular drive bays.

Two RAID cables are required (2 x UCSC-CABLE-S).

The upper blue line is a 0.8m cable (UCSC-CABLE-S) from the RAID controller SAS 0 connector to the first expander connector A (for drives 1 through 8).

The lower blue line is a 0.8m cable (UCSC-CABLE-S) from the RAID controller SAS 1 connector to the second expander connector B (for drives 9 through 16).

The green line is a cable from the RAID controller to the battery backup unit.

Figure C-3 RAID Controller Cabling Guidelines, Two Expanders and One Controller

 

1

2

3

 

 

 

334373

1

Expander transition cards

3 RAID controller card in PCIe slot 3

 

(shown with fan tray removed)

 

 

2

SCPM backup unit

 

 

 

(mounted to tray on air baffle)

 

 

Cisco UCS C420 Server Installation and Service Guide

 

OL-27640-01

C-5

 

Page 105
Image 105
Cisco Systems UCS C420 manual 334373