Appendix C RAID Controller Considerations
Supercap Power Modules (RAID Backup Units)
Supercap Power Modules (RAID Backup Units)
This server supports installation of two supercap power module (SCPM) backup units. The units mount to trays on the removable air baffle (see Replacing the Supercap Power Module (RAID Backup Unit), page
The SCPM is available only when using the LSI
Mixing Drive Types in RAID Groups
Table
Table
Mix of Drive Types |
|
in RAID Group | Allowed? |
|
|
SAS HDD + SATA HDD | Yes |
|
|
SAS SSD + SATA SSD | Yes |
|
|
HDD + SSD | No |
|
|
Best Practices For Mixing Drive Types in RAID Groups
For the best performance, follow these guidelines:
•Use either all SAS or all SATA drives in a RAID group.
•Use the same capacity for each drive in the RAID group.
•Never mix HDDs and SSDs in the same RAID group.
RAID Controller Cabling
The maximum two supported RAID controller cards should be populated in PCIe slots in the following order (see Figure
1.PCIe slot 3
2.PCIe slot 5
Refer to the following examples for cable routing guidelines:
•Example
•Example
•Example
For more information about transition cards, see Replacing a Modular Drive Bay Assembly, page