Appendix A Server Specifications
Environmental Specifications
Environmental Specifications
Table
Table | Environmental Specifications |
|
|
|
|
Description |
| Specification |
|
| |
Temperature, operating | 5ºC to 35ºC (41ºF to 95ºF) | |
|
| |
Temperature, nonoperating | ||
(when the server is stored) |
| |
|
| |
Humidity, nonoperating | 10% to 90% | |
|
| |
Altitude, operating | 0 m to 3048 m (0 ft to 10,000 ft) | |
Derated 1ºC for each 305 m |
| |
|
| |
Altitude, nonoperating | 0 m to 12,192 m (0 ft to 40,000 ft) | |
(when the server is stored) |
| |
|
|
|
Power Specifications
Table
Table | 1200 W Power Supply Specifications | |
|
|
|
Description |
| Specification |
|
| |
AC input voltage | 200 to 240 VAC nominal (Range: 180 to 264 VAC) | |
|
| |
Low AC input voltage | 100 to 120 VAC nominal (Range: 90 to 132 VAC) | |
(limited to 800 W system configurations) |
| |
|
| |
AC input frequency | 50 to 60 Hz nominal (Range: 47 to 63 Hz) | |
|
| |
Maximum | 10 A | |
|
| |
Maximum output power for each power | 1200 W (up to two power supplies can be installed) | |
supply |
|
|
|
| |
Power supply output voltage | Main power: 12 VDC | |
|
| Standby power: 12 VDC |
|
|
|
You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Cisco UCS C460 Server Installation and Service Guide
|
| ||
|
|