2.When the print density on the left and right sides is not equal (when the paper with a different width has been used):
The right head pressure viewed from the front of the panel can be adjusted with the head pressure
Adjustments
Normally, the left and right head pressure has already been
Adjustments are needed in the following cases:
1)When the print on the left side is too light, turn the head pressure adjust- screw clockwise.
2)When the print on the right side is too light, turn the head pressure
3)When the paper with a different small width is used, the contact between the print head and the platen becomes large, so the stepping motor will take a heavy load or the print head may scrape the platen. To avoid this, turn the head pressure
In addition, adjustments will be useful for preventing the ribbon wrinkling or the paper skew. For more information, contact our service personnel.