OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

9

6

1

2

3

4

10

7

5

5

8

Operating Controls & Indicators

ITEM #

DESCRIPTION

FUNCTION

1.

Low Water Indicator Light (Red)

When lit, indicates that the kettle is low on water and will not operate

 

 

in this condition (see RESERVOIR FILL PROCEDURES on page #28.

2.

On-Off Switch/

Turns kettle ON/OFF and allows the operator to adjust the kettle

 

Solid State

temperature in increments from 1 (Min.) to 10 (Max.).

 

Temperature Control

(see the TEMPERATURE RANGE CHART on page #8).

3.

Heat Indicator Light (Green)

When lit, indicates that the kettle's burner is on.

 

 

Cycles ON-OFF with burner.

4.

Ignition Failure Indicator Light

Indicates failure of heating system to ignite.

 

(Amber)

 

5.

Vacuum/Pressure Gauge

Indicate steam pressure in PSI inside steam jacket as well as

 

 

vacuum in inches of mercury.

6.

Pressure Relief Valve

This valve is used to vent the kettle and in the unlikely event there is

 

(not shown)

an excess steam build-up in the jacket, this valve opens

 

 

automatically to relieve this pressure.

7.

Water Level Sight Glass

Displays water level in steam jacket.

8.

Tilt Wheel

Used for tilting the kettle on hand tilt models. In power tilt models

 

 

there is a toggle switch in same location.

9.Flue

10.

Tangent Draw-Off Valve

Used for draining product or wash water from kettle. It is supplied as

 

 

standard equipment on stationary kettles and is optional on tilting kettles.