Specification Drawing -
Stationary,
A
4" (102 mm)
C
B
VALVE
OPENING
S
T
(I.D.)
H C
D
K
J
3 (77 mm) | H |
L
M
N
O
|
|
| FLOOR DRAIN | |
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| 12" (305 mm) WIDE x | |
P |
| 12" (305 mm) LONG | ||
|
|
| ||
|
|
|
|
|
3" (77 mm)
MINIMUM CLEARANCE
75º
G
(COVER
OPEN)
F
E
7/16" (11 mm) Ø | 4 | 7/8" |
3 HOLES ON | 124 | Ø mm |
3 1/8" (80 mm) Ø |
|
|
B.C.D. |
|
|
| 120º |
|
| TYP |
|
1 5/8" (42 mm) Ø |
|
|
1" (25 mm) |
| 9/16" |
MAX. ADJUSTMENT 14 mm
FLANGED FOOT DETAIL
| 4" (102 mm) | RECOMMENDED | |||
RECOMMENDED | FLOOR SLOPE | ||||
|
|
|
| 1" (26 mm) per 4' (1220 mm) | |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| PIPE DRAIN RECOMMENDED | |
|
|
|
| ||
|
|
|
| ||
|
|
|
| ||
|
|
|
| min. valve size plus 1" (26 mm) | |
|
|
|
|
|
|
UNIT SHOWN WITH OPTIONAL 2" TANGENT
SPRING ASSIST COVER AND HOT & COLD WATER FAUCET.
DIMENSIONS
GALS./ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LITERS | A | B | C | D | E | F | G | H | J | K | L | M | N | O | P | S | T I.D. | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
40 | IN | 35 1/8 | 37 | 32 1/4 | 40 1/2 | 9 1/4 | 16 | 71 1/2 | 9 9/16 | 17 | 3/4 25 15/16 10 | 3/8 | 18 5/8 | 26 7/8 | 28 1/2 | 4 5/8 | 24 1/2 | 26 | ||
150 | mm | 893 | 940 | 820 | 1029 | 235 | 407 | 1817 | 243 | 451 | 659 | 264 | 474 | 683 | 724 | 118 | 648 | 661 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
60 | IN | 38 1/4 | 39 | 34 1/4 | 43 1/2 | 8 3/4 | 14 1/4 | 75 | 8 15/16 19 | 1/8 29 5/16 10 | 3/8 | 18 5/8 | 27 7/8 | 30 1/4 | 5 1/4 | 27 | 29 1/2 | |||
225 | mm | 972 | 991 | 870 | 1105 | 223 | 362 | 1905 | 228 | 486 | 745 | 264 | 474 | 709 | 769 | 134 | 686 | 750 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
80 | IN | 41 5/8 | 42 3/8 | 35 1/2 | 45 1/2 | 8 3/4 | 15 1/2 | 79 | 9 1/4 | 20 | 3/4 | 32 1/4 | 10 | 3/8 | 18 5/8 | 29 5/8 | 31 1/2 | 6 5/8 | 29 | 33 |
300 | mm | 1058 | 1077 | 902 | 1156 | 223 | 394 | 2007 | 235 | 528 | 820 | 264 | 474 | 753 | 801 | 169 | 737 | 839 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
100 | IN | 44 | 43 1/2 | 36 1/2 | 47 1/2 | 8 3/4 | 15 1/2 | 83 1/2 | 9 1/8 | 21 | 7/8 | 34 5/8 | 10 | 3/8 | 18 5/8 | 31 1/4 | 32 1/2 | 7 1/2 | 30 1/2 | 35 1/2 |
375 | mm | 1118 | 1105 | 928 | 1207 | 22.3 | 394 | 2121 | 232 | 556 | 880 | 264 | 474 | 794 | 826 | 191 | 775 | 902 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GAS |
|
|
|
| ELECTRIC | WATER H C | CLEARANCE | ||||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| 1/2" dia. Soft | RIGHT = | 3" | |||
| NATURAL | PROPANE |
| B.T.U. RATING |
| H | C | ||||||
|
|
|
|
|
|
| amps | Copper Tubing | LEFT | = | 3" | ||
| Piping: 3/4" N.P.T. | Piping: 3/4" N.P.T. |
| 40 gal. | 140,000 |
| |||||||
|
|
|
|
|
| (each) | REAR | = | 3" | ||||
| Supply pressure: | Supply pressure: |
| 60 gal. |
|
|
|
|
| ||||
|
|
|
|
|
|
| When ordered | Allow 6" space minimum | |||||
| 4.00" W.C. minimum | 4.00" W.C. minimum |
| 80 gal. | 190,000 |
|
|
|
| with optional | from rear and sides when | ||
| 14.00" W.C. maximum | 14.00" W.C. maximum |
| 100 gal. |
|
|
|
|
| faucet. | located near combustible | ||
Manufacturer must be notified if unit will be operated above 2,000 ft. altitude. |
|
|
|
| walls. 12" recommended on | ||||||||
|
|
|
| right side for service | |||||||||
|
|
|
|
|
|
|
|
|
|
|
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.
3