Cleveland Range OES-20.20 cThe hot air heat circuit is energized, bThe fan circuit is energized

Models: OES-20.20 OEB-20.20

1 74
Download 74 pages 26.58 Kb
Page 45
Image 45

5With the combi in the Hot Air mode with time on the timer, the door closed and the start switch is depressed

a The front display will include a lighted bar under the Hot Air symbol

When the heat circuit is energized the heat symbol will be energized

The cooking mode symbol will be energized.

The time display will invert and begin to count down.

bThe fan circuit is energized

NOTE: If the temperature is less than 212 degrees F than fan will be pulsed on for 2 seconds every 60 seconds after the cabinet set temp (B6)

If the combi fan is in the normal setting 220 VAC is sent from terminal 5 on connector X11 through the normally closed auxiliary contacts of contactor K57 to the coils of contactors K55 and K56

The K55 and K56 contactors close sending 220 VAC through the Q56 overload to the motor and the motor turns at a high speed.

The normally closed auxiliary contacts of both K55 and K56 open preventing the K57 contactor from energizing.

If the combi fan is in the reduced setting 220 VAC is sent from terminal 6 on connector X11 through the normally closed auxiliary contacts of contactors K55 and K56 to the coil of contactor K57

The K57 contactor closes Sending 220 VAC through the Q57 thermal overload to the motor and the motor turns at a reduced speed.

The normally closed auxiliary contacts of K57 open preventing the K55 and K56 contactors from energizing.

For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary contacts of contactor K5 to the K50 contactor coil

K50 contactor closes and the motor turns CW

The normally closed auxiliary contacts on K50 open preventing the K5 contactor from energizing.

For 15 seconds the motor is de-energized and allowed to coast.

For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11 through the normally closed auxiliary contacts of contactor K50 to the K5 contactor coil

K5 contactor closes and the motor turns CCW

The normally closed auxiliary contacts on K5 open preventing the K50 contactor from energizing.

NOTE: If the door switch (S7) opens by the door opening, then the fan circuit is de-energized. Then the motor will be pulsed in the opposite direction to “break” the fan. This is to stop the fan quicker for the operator.

cThe hot air heat circuit is energized

220 VAC is sent from terminal 3 of connector X12 on the Control Board (A10) through the normally closed auxiliary contacts of K2 and K1 to the coil of Contactor K4 until the cabinet reaches the set temperature.

The contactor K4 closes and to legs of the 220 VAC is sent to the 18 KW element (E4)

Page 45
Image 45
Cleveland Range OES-20.20, OEB-20.20 cThe hot air heat circuit is energized, The cooking mode symbol will be energized