HotCup Operators’ Guide View Machine Info
November, 2007 87 6740001
KEYSWITCH The keyswitch input is active and configured as an inhibit.
MACH.TYPE 0 Machine type error displays machine type screen. NOTE: This is the
actual machine type screen. You may enter the correct machine type
number directly on this screen without further action.
D+J+WXYZ Configuration error; displays the machine configuration screen. NOTE: this
is the actual config screen. You may enter the correct config number
directly on this screen without further action.(Verify cup size and product
times in the product configuration screen).
TANK ER R Tank failed to fill or refill.
RING 1, 2 The cup ring is jammed.
MTR 1A1B2X Cup turrets are jammed.
NO CUPS 1, 2 Out of cups.
BREW JAM The brewer is jammed.
WAS TE PAI L The waste pail is full.
LOW WATER The water level in the tank is low.
COLD WATER Water in the tank is too cold to vend.
NO SENSOR Temperature sensor failed or missing.
No float Float sensor failed or missing.
WHIP 1 2 3 4 5 Whipper motor failure (motor 1, 2, 3, 4, 5)
DOOR JAM The automatic delivery door is jammed.
NO MECH Coin mech not detected - machine will not operate if configured for coin
mech
MECH COMM Incomplete coin mech communications check harness.
MECH.SENSOR Coin mech reporting a bad tube sensor replace mech.
MECH ROM Replace the coin mechanism.
MECH.ACCEPT Coin mechanism acceptor section is unplugged from the main body of the
coin mech. Connect the cable and cycle machine power OFF and then ON.
MECH JAM One or more coin tubes are jammed. Pay a coin from each tube until the
jam is cleared.
DEBIT CARD Card reader reporting error — machine will not operate if configured for
DEBIT ONLY.
CHECK DBV Bill validator reporting error — machine will not operate. Empty stacker,
clear jams, etc.