Graphics

===========================================================================

7.Follow the instructions on the screen to cycle through the screens, to return to the list and choose another item, or to print the information.

Chapter 2.6 Diagnostic Error Codes

Diagnostic error codes occur if the system recognizes a problem while running the Compaq Diagnostic program. These error codes help identify possibly defective subassemblies.

Tables 2-4 through 2-16 list possible error codes, a description of the error condition, and the action required to resolve the error condition.

IMPORTANT: Retest the system after completing each step. If the problem has been resolved, do not proceed with the remaining steps.

For assistance in the removal and replacement of a particular subassembly, see Chapter 5, "Removal and Replacement Procedures."

Table 2-4. Processor Test Error Codes

===========================================================================

Error Code DescriptionRecommended Action

===========================================================================

101 - xx CPU test failed Replace the processor board and retest.

---------------------------------------------------------------------------

102 - xx

Coprocessor or

1.

Run the

Configuration

and

 

Weitek Error

 

Diagnostics

Utilities.

 

 

 

2.

Replace

the

processor

board and

 

 

 

retest.

 

 

 

---------------------------------------------------------------------------

103

- xx

DMA page registers

Replace the system board and retest.

 

 

test failed

 

104

- xx

Interrupt controller

 

 

 

master test failed

 

105

- xx

Port 61 error

 

106

- xx

Keyboard controller

 

 

 

self-test failed

 

107

- xx

CMOS RAM test

 

 

 

failed

 

108

- xx

CMOS interrupt test

 

 

 

failed

 

109

- xx

CMOS clock test

 

 

 

failed