failed

 

2404

- xx

Video

character set

 

 

test failed

2405

- xx

Video

80 x 25 mode

 

 

9 x 14 character

 

 

cell test failed

2406

- xx

Video

80 x 25 mode

 

 

8 x 8

character

 

 

cell test failed

2408

- xx

Video

320 x 200

 

 

mode color set 0

 

 

test failed

2409

- xx

Video

320 x 200

 

 

mode color set 1

 

 

test failed

Diagnostics Utilities.

2.Replace the display assembly and retest.

3.Replace the system board and retest.

2410

- xx

Video 640 x

200

 

 

mode test failed

2411

- xx

Video screen

 

 

 

memory page

test

 

 

failed

 

2412

- xx

Video gray scale

 

 

test failed

 

2414

- xx

Video white

screen

 

 

test failed

 

2416

- xx

Video noise

 

 

 

pattern test

 

 

 

failed

 

2418

- xx

ECG/VGC memory

 

 

test failed

 

---------------------------------------------------------------------------

Error Code DescriptionRecommended Action

---------------------------------------------------------------------------

2419

- xx

ECG/VGC ROM checksum

The following steps apply to error

 

 

test failed

codes 2402 - xx through 2456 - xx:

2421

- xx

ECG/VGC 640 x 200

1.

Run the Configuration and

 

 

graphics mode test

 

Diagnostics Utilities.

 

 

failed

2.

Disconnect external monitor and

 

 

 

 

test with internal LCD display.

2422

- xx

ECG/VGC 640 x 350

3.

Check display jumpers on the

 

 

16 color set test

 

processor board (see Chapter 5.)

 

 

failed

4.

Replace the display assembly and

 

 

 

 

retest.

2423

- xx

ECG/VGC 640 x 350

5.

Replace the system board and retest.

 

 

64 color set test

 

 

 

 

failed

 

 

2424

- xx

ECG/VGC monochrome

 

 

 

 

text mode test