Working from a CLI
AlterPath BladeManager Manual 5-7
SETCONS - sets console connection. For example:
[root@APM_Paulo root]# setcons
APM Console Configuration Utility
---------------------------------
Current Parameters: 9600, 8n1, vt100
Press <ENTER> if you wish to change it, or [Q<ENTER>]
to quit:
Enter Baud Rate (in bps) [9600]:
Enter Word Length (5, 6, 7 or 8) [8]:
Enter Parity (even, odd or no) [no]:
Enter Stop Bits (1 or 2) [1]:
Enter Terminal Type [vt100]:
WARNING: make sure you're setting valid values for the
console parameters, or you may make your console
inaccessible!
Current Parameters: 9600, 8n1, vt100
Do you wish to save these parameters? (y/N)
SETDATETIME - sets the system date and time based on the selected time
zone. For example:
[root@APM_Paulo root]# setdatetime
Please choose the time zone where this machine is located.
1) Africa 18) Eire 35) Jamaica 52) ROC
2) America 19) Etc 36) Japan 53) ROK
3) Antarctica 20) Europe 37) Kwajalein 54) Singapore
4) Arctic 21) Factory 38) Libya 55) System
5) Asia 22) GB 39) MET 56) Turkey
6) Atlantic 23) GB-Eire 40) MST 57) UCT
7) Australia 24) GMT 41) MST7MDT 58) US
8) Brazil 25) GMT+0 42) Mexico 59) UTC
9) CET 26) GMT-0 43) Mideast 60) Universal
10) CST6CDT 27) GMT0 44) NZ 61) W-SU
11) Canada 28) Greenwich 45) NZ-CHAT 62) WET
12) Chile 29) HST 46) Navajo 63) Zulu
13) Cuba 30) Hongkong 47) PRC 64) iso3166.tab
14) EET 31) Iceland 48) PST8PDT 65) posix
15) EST 32) Indian 49) Pacific 66) posixrules