A: BladeManager Hardware Specifications

 

Expansion Slots

Two 66 MHz/64-bit PCI-X slots (one low profile

 

half-length, one full-height three-quarter-length)

Video Controller

ATI Radeon 7000M IGP video on system board

 

Compatible with SVGA and VGA

 

16 MB DD-SDRAM video memory

Power

300 watt (110 or 220 V ac auto sensing)

Operating Environment

Server on: 10o to 35oC (50o to 95oF)

Air Temperature

 

Altitude: 0 to 914 m (2998.7 ft)

 

Server off: -40oto 60oC (-104oto 140oF)

 

Maximum altitude: 2133 m (6998 ft)

Humidity

Server on: 8% to 80%

 

Server off: 8% to 80%

Heat Output

Approximate heat output in British thermal units

 

(Btu) per hour:

 

Minimum configuration: 307 Btu (90 watts)

 

Maximum configuration: 850 Btu (250 watts)

Acoustical noise emissions

Sound power, idling: 6.5 bel maximum

 

Sound power, operating: 6.5 bel maximum

Certifications

FCC Class A, CE

Notes:

Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.

These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate.

A-2

AlterPath BladeManager Manual

Page 200
Image 200
Cyclades AlterPath BladeManager user manual Air Temperature