PRELIMINARY CY14B101P
Document #: 001-44109 Rev. *B Page 27 of 32
Software Controlled STORE/RECALL Cycles
Parameter Description CY14B101P Unit
Min Max
t
RECALL
RECALL Duration 200 µs
t
SS [11, 13]
Soft Sequence Processing Time 100 µs
Figure 28. Software STORE Cycle
[13]
Figure 29. Software RECALL Cycle
[13]
0 0 1 1 1 1 0 0
CS
SCK
SI
RWI
Hi-Z
0 1 2 3 4 5 6 7
RDY
tSTORE
0 1 1 0 0 0 0 0
CS
SCK
SI
0 1 2 3 4 5 6 7
RWI
Hi-Z
RDY
tRECALL
Notes
12.This is the amount of time it takes to take action on a soft sequence command. Vcc power must remain HIGH to effectively register command.
13.Commands such as STORE and RECALL lock out IO until operation is complete which further increases this time. See the specific command.
[+] Feedback