Cypress CY7C1442AV33 Switching Characteristics Over the Operating Range 24, Min Max, Set-up Times

Models: CY7C1440AV33 CY7C1446AV33 CY7C1442AV33

1 31
Download 31 pages 60.7 Kb
Page 20
Image 20

CY7C1440AV33

CY7C1442AV33

CY7C1446AV33

Switching Characteristics Over the Operating Range [24, 25]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–250

–200

–167

 

Parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.

Max

Min.

Max.

Min.

Max

 

 

 

 

 

 

 

 

 

 

tPOWER

 

VDD(Typical) to the first Access[20]

1

 

1

 

1

 

ms

Clock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tCYC

 

Clock Cycle Time

4.0

 

5

 

6

 

ns

tCH

 

Clock HIGH

1.5

 

2.0

 

2.4

 

ns

tCL

 

Clock LOW

1.5

 

2.0

 

2.4

 

ns

Output Times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tCO

 

Data Output Valid After CLK Rise

 

2.6

 

3.2

 

3.4

ns

tDOH

 

Data Output Hold After CLK Rise

1.0

 

1.5

 

1.5

 

ns

t

 

Clock to Low-Z[21, 22, 23]

1.0

 

1.3

 

1.5

 

ns

CLZ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t

 

Clock to High-Z[21, 22, 23]

 

2.6

 

3.0

 

3.4

ns

CHZ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tOEV

 

 

 

LOW to Output Valid

 

2.6

 

3.0

 

3.4

ns

OE

tOELZ

 

 

 

LOW to Output Low-Z[21, 22, 23]

0

 

0

 

0

 

ns

OE

tOEHZ

 

 

 

HIGH to Output High-Z[21, 22, 23]

 

2.6

 

3.0

 

3.4

ns

OE

Set-up Times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tAS

 

Address Set-up Before CLK Rise

1.2

 

1.4

 

1.5

 

ns

tADS

 

 

 

 

 

 

 

 

 

 

 

 

 

Set-up Before CLK Rise

1.2

 

1.4

 

1.5

 

ns

ADSC,

ADSP

tADVS

 

 

 

 

 

Set-up Before CLK Rise

1.2

 

1.4

 

1.5

 

ns

ADV

tWES

 

 

 

 

 

 

 

 

 

 

 

 

 

X Set-up Before CLK Rise

1.2

 

1.4

 

1.5

 

ns

GW,

BWE,

BW

tDS

 

Data Input Set-up Before CLK Rise

1.2

 

1.4

 

1.5

 

ns

tCES

 

Chip Enable Set-up Before CLK Rise

1.2

 

1.4

 

1.5

 

ns

Hold Times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tAH

 

Address Hold After CLK Rise

0.3

 

0.4

 

0.5

 

ns

tADH

 

 

 

 

 

 

 

 

 

 

 

Hold After CLK Rise

0.3

 

0.4

 

0.5

 

ns

ADSP,

ADSC

tADVH

 

 

 

 

Hold After CLK Rise

0.3

 

0.4

 

0.5

 

ns

ADV

tWEH

 

 

 

 

 

 

 

 

 

 

 

 

 

X Hold After CLK Rise

0.3

 

0.4

 

0.5

 

ns

GW,

BWE,

BW

tDH

 

Data Input Hold After CLK Rise

0.3

 

0.4

 

0.5

 

ns

tCEH

 

Chip Enable Hold After CLK Rise

0.3

 

0.4

 

0.5

 

ns

Notes:

20.This part has a voltage regulator internally; tPOWER is the time that the power needs to be supplied above VDD(minimum) initially before a read or write operation can be initiated.

21.tCHZ, tCLZ,tOELZ, and tOEHZ are specified with AC test conditions shown in (b) of AC Test Loads. Transition is measured ± 200 mV from steady-state voltage.

22.At any given voltage and temperature, tOEHZ is less than tOELZ and tCHZ is less than tCLZ to eliminate bus contention between SRAMs when sharing the same data bus. These specifications do not imply a bus contention condition, but reflect parameters guaranteed over worst case user conditions. Device is designed to achieve High-Z prior to Low-Z under the same system conditions.

23.This parameter is sampled and not 100% tested.

24.Timing reference level is 1.5V when VDDQ = 3.3V and is 1.25V when VDDQ = 2.5V.

25.Test conditions shown in (a) of AC Test Loads unless otherwise noted.