CY7C604XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC I2C Specifications

 

 

 

 

 

 

Table 20 lists guaranteed maximum and minimum specifications for the entire voltage and temperature ranges.

 

 

Table 20. AC Characteristics of the I2C SDA and SCL Pins

 

 

 

 

 

 

Symbol

 

 

Description

Standard Mode

Fast Mode

Units

 

 

Min

Max

Min

 

Max

 

 

 

 

 

 

FSCLI2C

SCL Clock Frequency

0

100

0

 

400

kHz

THDSTAI2C

Hold Time (repeated) START Condition. After this period,

4.0

0.6

 

μs

 

the first clock pulse is generated.

 

 

 

 

 

 

TLOWI2C

LOW Period of the SCL Clock

4.7

1.3

 

μs

THIGHI2C

HIGH Period of the SCL Clock

4.0

0.6

 

μs

TSUSTAI2C

Setup Time for a Repeated START Condition

4.7

0.6

 

μs

THDDATI2C

Data Hold Time

0

0

 

μs

TSUDATI2C

Data Setup Time

250

100(22)

 

ns

TSUSTOI2C

Setup Time for STOP Condition

4.0

0.6

 

μs

TBUFI2C

Bus Free Time Between a STOP and START Condition

4.7

1.3

 

μs

TSPI2C

Pulse Width of Spikes are Suppressed by the Input Filter

0

 

50

ns

Figure 8. Definition of Timing for Fast/Standard Mode on the I2C Bus

SDA

TLOWI2C

 

 

 

 

 

TSUDATI2C

 

 

 

 

 

SCL

 

 

 

 

S

T

T

T

TSUSTAI2C

HDDATI2C

 

 

HDSTAI2C

 

HIGHI2C

 

THDSTAI2C

Sr

TSPI2C

 

TBUFI2C

 

 

TSUSTOI2C

P

S

 

Notes

22.A fast mode I2C bus device can be used in a standard mode I2C bus system, but the requirement tSU;DAT Š 250 ns must then be met. This is automatically the case if the device does not stretch the LOW period of the SCL signal. If such device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line trmax + tSU;DAT = 1000 + 250 = 1250 ns (according to the standard mode I2C bus specification) before the SCL line is released.

Document Number: 001-12395 Rev *H

Page 24 of 30

[+] Feedback

Page 24
Image 24
Cypress CY7C604XX manual AC I2C Specifications