CY7C604XX
Document Number: 001-12395 Rev *H Page 24 of 30
AC I2C Specifications
Tabl e 20 lists guaranteed maximum and minimum specifications for the entire voltage and temperature ranges.
Figure 8. Definition of Timing for Fast/Standard Mode on the I2C Bus
Table 20. AC Characteristics of the I2C SDA and SCL Pins
Symbol Description Standard Mode Fast Mode Units
Min Max Min Max
FSCLI2C SCL Clock Frequency 0 100 0 400 kHz
THDSTAI2C Hold Time (repeated) START Condition. After this period,
the first clock pulse is generated. 4.0 –0.6μs
TLOWI2C LOW Period of the SCL Clock 4.7 –1.3μs
THIGHI2C HIGH Period of the SCL Clock 4.0 –0.6μs
TSUSTAI2C Setup Time for a Repeated START Condition 4.7 –0.6μs
THDDATI2C Data Hold Time 0 –0μs
TSUDATI2C Data Setup Time 250 –100
(22) –ns
TSUSTOI2C Setup Time for STOP Condition 4.0 –0.6μs
TBUFI2C Bus Free Time Between a STOP and START Condition 4.7 –1.3μs
TSPI2C Pulse Width of Spikes are Suppressed by the Input Filter 0 50 ns
SDA
SCL
SSr SP
TBUFI2C
TSPI2C
THDSTAI2C
TSUSTOI2C
TSUSTAI2C
TLOWI2C
THIGHI2C
THDDATI2C
THDSTAI2C
TSUDATI2C
Notes
22.A fast mode I2C bus device can be used in a standard mode I2C bus system, but the requirement tSU;DAT Š 250 ns must then be met. This is automatically the case
if the device does not stretch the LOW period of the SCL signal. If such device does stretch the LOW period of the SCL signal, it must output the next data bit to the
SDA line trmax + tSU;DAT = 1000 + 250 = 1250 ns (according to the standard mode I2C bus specification) before the SCL line is released.
[+] Feedback