Cypress manual CYV15G0404RB AC Electrical Characteristics

Models: CYV15G0404RB

1 27
Download 27 pages 27.19 Kb
Page 21
Image 21
CYV15G0404RB AC Electrical Characteristics

CYV15G0404RB

CYV15G0404RB AC Electrical Characteristics

Parameter

Description

Min

Max

Unit

 

 

 

 

 

CYV15G0404RB Receiver LVTTL Switching Characteristics Over the Operating Range

 

 

 

 

 

 

 

 

 

 

fRS

 

 

RXCLKx± Clock Output Frequency

9.75

150

MHz

tRXCLKP

RXCLKx± Period = 1/fRS

6.66

102.56

ns

tRXCLKD

RXCLKx± Duty Cycle Centered at 50% (Full Rate and Half Rate)

–1.0

+1.0

ns

tRXCLKR [14]

RXCLKx± Rise Time

0.3

1.2

ns

tRXCLKF [14]

RXCLKx± Fall Time

0.3

1.2

ns

t

 

[18]

Status and Data Valid Time to RXCLKx± (RXRATEx = 0) (Full Rate)

5UI–2.0[19]

 

ns

RXDv–

 

 

 

 

 

 

 

 

Status and Data Valid Time to RXCLKx± (RXRATEx = 1) (Half Rate)

5UI–1.3[19]

 

ns

t

 

[18]

Status and Data Valid Time to RXCLKx± (RXRATEx = 0)

5UI–1.8[19]

 

ns

RXDv+

 

 

 

 

 

 

 

 

Status and Data Valid Time to RXCLKx± (RXRATEx = 1)

5UI–2.6[19]

 

ns

fROS

 

 

RECLKOx Clock Frequency

19.5

150

MHz

tRECLKO

RECLKOx Period = 1/fROS

6.66

51.28

ns

tRECLKOD

RECLKOx Duty Cycle centered at 60% HIGH time

–1.9

0

ns

CYV15G0404RB TRGCLKx Switching Characteristics Over the Operating Range

 

 

 

 

 

 

 

 

 

 

fTRG

 

 

TRGCLKx Clock Frequency

19.5

150

MHz

TRGCLK

TRGCLKx Period = 1/fREF

6.6

51.28

ns

tTRGH

 

TRGCLKx HIGH Time (TRGRATEx = 1)(Half Rate)

5.9

 

ns

 

 

 

TRGCLKx HIGH Time (TRGRATEx = 0)(Full Rate)

2.9[14]

 

ns

tTRGL

 

 

TRGCLKx LOW Time (TRGRATEx = 1)(Half Rate)

5.9

 

ns

 

 

 

TRGCLKx LOW Time (TRGRATEx = 0)(Full Rate)

2.9[14]

 

ns

tTRGD[20]

TRGCLKx Duty Cycle

30

70

%

t

[14, 15, 16, 17]

TRGCLKx Rise Time (20%–80%)

 

2

ns

TRGR

 

 

 

 

 

t

[14, 15, 16, 17]

TRGCLKx Fall Time (20%–80%)

 

2

ns

TRGF

 

 

 

 

 

 

tTRGRX[21]

TRGCLKx Frequency Referenced to Received Clock Frequency

–0.15

+0.15

%

CYV15G0404RB Bus Configuration Write Timing Characteristics Over the Operating Range

 

 

 

 

 

 

 

tDATAH

Bus Configuration Data Hold

0

 

ns

tDATAS

Bus Configuration Data Setup

10

 

ns

tWRENP

Bus Configuration WREN Pulse Width

10

 

ns

CYV15G0404RB JTAG Test Clock Characteristics Over the Operating Range

 

 

 

 

 

 

 

 

 

 

fTCLK

 

 

JTAG Test Clock Frequency

 

20

MHz

tTCLK

 

 

JTAG Test Clock Period

50

 

ns

Notes

14.Tested initially and after any design or process changes that may affect these parameters, but not 100% tested.

15.The ratio of rise time to falling time must not vary by greater than 2:1.

16.For a given operating frequency, neither rise nor fall specification can be greater than 20% of the clock cycle period or the data sheet maximum time.

17.All transmit AC timing parameters measured with 1ns typical rise time and fall time.

18.Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.

19.Receiver UI (Unit Interval) is calculated as 1/(fTRG * 20) (when TRGRATEx = 1) or 1/(fTRG * 10) (when TRGRATEx = 0). In an operating link this is equivalent to tB.

20.The duty cycle specification is a simultaneous condition with the tREFH and tREFL parameters. This means that at faster character rates the TRGCLKx± duty cycle cannot be as large as 30%–70%.

21.TRGCLKx± has no phase or frequency relationship with the recovered clock(s) and only acts as a centering reference to reduce clock synchronization time. TRGCLKx± must be within ±1500 PPM (±0.15%) of the transmitter PLL reference (REFCLKx±) frequency. Although transmitting to a HOTLink II receiver channel necessitates the frequency difference between the transmitter and receiver reference clocks to be within ±1500-PPM, the stability of the crystal needs to be within the limits specified by the appropriate standard when transmitting to a remote receiver that is compliant to that standard.

Document #: 38-02102 Rev. *C

Page 21 of 27

[+] Feedback

Page 21