Handshaking

Review your system documentation to identify handshaking requirements, and use these labels to change the settings if required. The following brief descriptions explain each selection.

Hardware Control

CTS/RTS Flow Control — is hardware handshaking. The scanner activates the RTS (Ready to Send) line when it is ready to send data to the host. The scanner waits for an active Clear to Send (CTS) signal from the host before transmitting data. If hardware control is disabled, CTS/RTS communication will not take place. If the host deactivates the CTS line during data trans- mission, the host will receive additional characters for no more than 2msec1.

 

CTS/RTS Flow Control

 

Data

Label Transmission

Disabled

Xmission

Label Transmission

 

 

Active

 

 

 

CTS

 

Inactive

 

 

 

 

 

 

CTS Scan Control — is also a hardware control. When scan control is enabled, label transmission is disabled until CTS is asserted and de-asserted.

 

 

CTS Scan Control

Will not scan again

 

 

 

 

 

 

until toggle

Data

Label 1

Label 1

Label 2

 

 

Disabled until

 

 

 

Assert

 

CTS

De-assert

 

1 Varies slightly depending upon baud rate selected.