32
QuickScan 6000/6000 Plus
Label Transmit Format Configuration Items

(RS-232 and Keyboard Wedge Interfaces Only)

If you need to send information in addition to label data, the scanner can
be configured to transmit prefixes and/or suffixes as well as symbology
specific identifier characters (Label I.D.).

Prefix & Suffix

As the examples below show, none, one or two symbology specific ASCII
characters can be added to the beginning of label in addition to multiple
prefix and suffix characters.
NOTE
Using this feature requires a thorough understanding
of your specific system requirements.
The options available using this feature are:
Symbology specific (0 - 2) characters + label data
PP + label data
Non-symbology specific characters (1-2) as a prefix + label
data
CpCp + label data
Label data + non-symbology specific characters (0-2) as a
suffix
label data + CsCs
Non-symbology specific characters (1-2) as a prefix + symbol-
ogy specific characters (0-2) + label data
CpCp + PP + label data
Symbology specific characters (0-2) + label data + non-
symbology specific characters (1-2) as a suffix
PP + label data + CsCs