Dell 745N manual Hardware-RAID NAS System Drive Configuration, Front-Panel RAID Volume LED Codes

Models: 745N

1 89
Download 89 pages 27.19 Kb
Page 40
Image 40

partitions. Data can be stored on all four SATA hard drives in partitions that are configured as RAID 5 by default.

Table 3-1. Software RAID Default Hard-Drive Partitions

Volume

Hard Drives and RAID Layout

Description

 

 

 

C:

0 and 1: RAID 1

Primary operating system volume

D:

2 and 3: RAID 1

Recovery operating system volume

 

 

 

E:

0, 1, 2, and 3: RAID 5

Data volume

 

 

 

Figure 3-1. Software RAID Default Hard-Drive Partitions

Each hard drive has front-panel LEDs that provide information about the drive and RAID volume(s). See "Front-Panel Indicators" in the Installation and Troubleshooting Guide for the location of the LEDs. Table 3-2 provides the front-panel RAID volume LED codes.

Table 3-2. Front-Panel RAID Volume LED Codes

Volume Condition

LED Status Indicator Pattern

 

 

The drive bay is empty.

Off

 

 

The RAID volume is online.

Steady green

 

 

The RAID volume is rebuilding.

Blinking green

 

 

The drive has failed.

Blinking amber

 

 

Hardware-RAID NAS System Drive Configuration

A NAS system with hardware RAID configuration contains four SATA hard drives that are connected to a CERC SATA RAID controller. Unlike the software-RAID NAS system where Windows Storage Server 2003 controls the hard drives, the drives in the hardware-RAID NAS system are controlled by a RAID controller card installed in a PCI expansion slot. All four CERC-SATA hard drives appear as only two virtual disks to the operating system. See Table 3-3 and Figure 3-2. The operating system and boot sectors are installed on one RAID 5 volume that is spanned across the four CERC-SATA hard drives. Data can be stored on the other RAID 5 volume that is also spanned across the four CERC-SATA hard drives.

NOTE: RAID 1 hard-drive configurations are not supported on hardware-RAID NAS systems.

Table 3-3. Hardware RAID Default Hard-Drive Partitions

Volume

Hard Drives and RAID Layout

Description

 

 

 

C:

0, 1, 2, and 3: RAID 5

Primary operating system volume on virtual disk 0 (10 GB)

 

 

 

D:

0, 1, 2, and 3: RAID 5

Data volume on virtual disk 1

 

 

 

Figure 3-2. Hardware RAID Default Hard-Drive Partitions

Page 40
Image 40
Dell 745N manual Hardware-RAID NAS System Drive Configuration, Software RAID Default Hard-Drive Partitions