About Your System 33
8104 Yes Warning! Port
60h/64h
emulation is
not supported
by this USB
Host
Controller!!!
See "Troubleshooting a USB Device" on
page108.
If the problem persists, see "Getting
Help" on page131.
8105 Yes Warning! EHCI
controller
disabled. It
requires 64-
bit data
support in
the BIOS.
See "Troubleshooting a USB Device" on
page108.
If the problem persists, see "Getting
Help" on page131.
8301 Yes Not enough
space in
Runtime area!
SMBIOS data
will not be
available.
See "Troubleshooting System Memory"
on page115.
If the problem persists, see "Getting
Help" on page131.
8302 Yes Not enough
space in
Runtime area!
SMBIOS data
will not be
available.
See "Troubleshooting System Memory"
on page115.
If the problem persists, see "Getting
Help" on page131.
8601 Yes Error: iBMC
Not
Responding
Remove AC power to the system for
10seconds and restart the system.
If the problem persists, see "Getting
Help" on page131.
Code Log in iBMC Error Message Corrective Action
book.book Page 33 Monday, April 12, 2010 3:38 PM