Back-Panel Connectors (Per RAID Controller
Module)
NOTE: SAS and FC connections to the same
host is not supported.
Two SAS OUT ports, it is recommended that you
use the first port for expansion to an additional
PowerVault MD3060e expansion enclosure. Only
one expansion port is supported at any given time.
NOTE: SAS connectors are SFF-8644
compliant.
Serial connector (debug port) One mini USB port
NOTE: For technical support use only.
Management Ethernet connector One 100/1000 Mbps Ethernet connection for out-
of-band management of the enclosure and the
second Ethernet port is reserved.
FC connectors Four FC IN ports to connect hosts
NOTE: Directly attaching to the FC ports is
not supported. The host connection must use
a FC switch.
Power
AC power supply (per power supply)
Wattage 1755 W
Heat dissipation (maximum)
NOTE: Heat dissipation is calculated
using the power supply wattage rating.
The heat dissipation values are for the
entire system which includes chassis and
two controllers.
5988 BTU/hr
Voltage
NOTE: This system is also designed to be
connected to IT power systems with a
phase to phase voltage not exceeding
230 V.
220 V AC, autoranging, 50 Hz/60 Hz
Battery 6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery
52