Back-Panel Connectors (Per RAID Controller Module)

Serial connector (debug port)

Management Ethernet connector

FC connectors

NOTE: SAS and FC connections to the same host is not supported.

Two SAS OUT ports, it is recommended that you use the first port for expansion to an additional PowerVault MD3060e expansion enclosure. Only one expansion port is supported at any given time.

NOTE: SAS connectors are SFF-8644 compliant.

One mini USB port

NOTE: For technical support use only.

One 100/1000 Mbps Ethernet connection for out- of-band management of the enclosure and the second Ethernet port is reserved.

Four FC IN ports to connect hosts

NOTE: Directly attaching to the FC ports is not supported. The host connection must use a FC switch.

Power

AC power supply (per power supply)

Wattage

1755 W

Heat dissipation (maximum)

5988 BTU/hr

NOTE: Heat dissipation is calculated using the power supply wattage rating. The heat dissipation values are for the entire system which includes chassis and two controllers.

Voltage

220 V AC, autoranging, 50 Hz/60 Hz

NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.

Battery

6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery