5In the rare case that the LEDs on the expansion enclosure do not stop blinking, from the Array Management Window, select Storage ArrayBlinkStop All Indications.

If the LEDs successfully stop blinking, a confirmation message appears.

6Click OK.

Capturing the State Information

Use the TroubleshootingCapture State Information option to capture information about the current state of your storage array and save the captured information to a text file. You can then send the captured information to your Technical Support representative for analysis.

Potential to cause an unresponsive storage array – The State Capture option can cause a storage array to become unresponsive to both the host and the storage management station. Use this option only under the guidance of your Technical Support representative.

1From the AMW, select AdvancedTroubleshooting Capture State Information.

2Read the information in the Confirm State Capture dialog, and type yes to continue.

3In the Specify filename text box, enter a name for the file to be saved, or browse to a previously saved file if you want to overwrite an existing file.

Use the convention filename.dmp for the name of the file. The suffix

.dmp is added to the file automatically if you do not specify a suffix for the file.

4Click Start.

NOTE: Each test shows a status of Executing while it is in progress. The test then shows Completed when it successfully finishes. If any of the tests cannot be completed, a status of Failed appears in the Execution summary window.

5Monitor the progress and completion status of all of the tests. When they finish, click OK to close the State Capture dialog.

Clicking Cancel stops the state capture process, and any remaining tests do not complete. Any test information that has been generated to that point is saved to the state capture file.

234

Troubleshooting: Your Storage Array Software

Page 234
Image 234
Dell MD3200, MD3220 owner manual Capturing the State Information, 234