Dialogic TX4000 PCI SS7 installation manual Configuring SS7 Monitor mode

Models: TX4000 PCI SS7

1 48
Download 48 pages 27.97 Kb
Page 18
Image 18

Installing the TX 4000 board

TX 4000 PCI SS7 Network Interface Board Installation Manual

The following illustration shows the H.100 termination DIP switch:

S2

ON

12 34 567 8

OFF

Configuring SS7 Monitor mode

DIP switch S3 controls the SS7 Monitor mode. The DIP switch is located on the front of the board, to the right of the T1/E1 trunk connectors. By default, all S3 switches are set to the ON position. This setting disables SS7 Monitor mode. When SS7 Monitor mode is disabled, the TX board is an active participant in the network.

To enable SS7 Monitor mode, set the S3 switches to the OFF position. In this mode, the board becomes a passive listening device that monitors network traffic. For information on connecting the monitoring server (with an installed TX board) to the network and installing the SS7 Monitor software, refer to the Dialogic® NaturalAccess™ SS7 Monitor Developer's Reference Manual and to the Installing Dialogic® NaturalAccess™ SS7 Monitor Software instructions.

Note: The switches in DIP switch S3 must be set to either all ON or all OFF.

The following illustration shows the Monitor mode DIP switch:

S3

ON

1 2 3 4

OFF

18

Dialogic Corporation

Page 18
Image 18
Dialogic TX4000 PCI SS7 installation manual Configuring SS7 Monitor mode