Do not work on your telephone wiring if you wear a pacemaker. Telephone lines carry electrical current.

Installation of inside wire may bring you close to electrical wire, conduit, terminals and other electrical facilities. Extreme caution must be used to avoid electrical shock from such facilities. You must avoid contact with all such facilities.

Telephone wiring must be at least 6 feet from bare power wiring or lightning rods and associated wires, and at least 6 inches from other wire (antenna wires, doorbell wires, wires from transformers to neon signs), steam or hot water pipes, and heating ducts.

Before working with existing inside wiring, check all electrical outlets for a square telephone dial light transformer and unplug it from the electrical outlet. Failure to unplug all telephone transformers can cause electrical shock.

Do not place a jack where it would allow a person to use the telephone while in a bathtub, shower, swimming pool, or similar hazardous location.

Protectors and grounding wire placed by the service provider must not be connected to, removed, or modified by the customer.

 

Do not touch uninsulated telephone wiring if lightning is

 

likely!

Important!

External Wiring

Any external communications wiring you may install needs to

be constructed to all relevant electrical codes. In the United

 

States this is the National Electrical Code Article 800.

 

Contact a licensed electrician for details.

Specifications

PortServer TS 8/16

Power Requirements

(Standard Models)

2-contact barrel

+9 to +30 VDC 525 mA (max) external power

connector

supply

 

 

 

 

Environmental

PortServer TS 8

PortServer TS 16

 

 

 

Ambient

0 to 50° Celsius

temperature

32 to 131° Fahrenheit

 

 

 

Relative

5% to 90% non-condensing

humidity

 

 

 

 

 