EM78P156N
OTP ROM
Four conditions exist with the Operating Current ICC1 to ICC4. These conditions are as follows: ICC1: VDD=3V, Fosc=32K Hz, 2 clocks, WDT disable
ICC2: VDD=3V, Fosc=32K Hz, 2 clocks, WDT enable
ICC3: VDD=5V, Fosc=4M Hz, 2 clocks, WDT enable
ICC4: VDD=5V, Fosc=10M Hz, 2 clocks, WDT enable
Typical ICC1 and ICC2 vs. Temperature
15
12 |
| Typ ICC2 |
|
Current (uA)
9
6
3
0
Typ ICC1
0 | 20 | 40 | 60 | 80 |
Temperature (℃)
Fig. 26 Typical operating current (ICC1 and ICC2) vs. Temperature
Current (uA)
Maximum ICC1 and ICC2 vs. Temperature
21 |
| |
| ||
18 |
| |
| ||
15 |
| |
Max ICC2 | ||
| ||
12 |
| |
Max ICC1 | ||
9 | ||
| ||
| ||
6 |
| |
|
0 | 20 | 40 | 60 | 80 |
Temperature (℃)
Fig. 27 Maximum operating current (ICC1 and ICC2) vs. Temperature
This specification is subject to change without prior notice. 46 | 07.29.2004 (V1.2) |