System Status Register 3

System Status Register 3

The MVME6100 board system status register 3 provides the board software-controlled reset functions.

Table 1-9. System Status Register 3

REG

 

 

System Status Register 3- 0xF1100002

 

 

 

 

 

 

 

 

 

 

 

BIT

7

6

 

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

FIELD

_RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOARD

RSVD

 

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

 

 

 

 

 

 

 

 

 

 

OPER

R/W

R

 

R

R

R

R

R

R

 

 

 

 

 

 

 

 

 

 

RESET

0

0

 

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

BOARD_RESET

Board Reset. Setting this bit will force a hard reset of the MVME6100 board. This bit will clear automatically when the board reset is complete. This bit will always be cleared during a read.