Troubleshooting
Install
Continuous Signal
Noise and Signal Errors
Field Wiring
Warranty
Internal Access
Test Setup
Regulator Assembly
Calibration Precaution
Page 1
Image 1
Instruction Manual
CI-9110
Mar. 2007
Series 9110
Remote Set Regulator Model
9110-00A
www.EmersonProcess.com/Bristol
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
Remote Set Regulator Model 9110-00A
IMPORTANT! Read Instructions Before Starting
Warranty
Bristol Inc
Mail
Phone
Bristol Inc. Repair Authorization Form off-line completion
Training
860 860 945-2213 FAX
Telephone Support Technical Questions
Visit our Site on the World Wide Web Training Courses
Model 9110-00A Remote SET Regulator
Supplemental Instructions
Theory of Operation
Product Description
Analog Regulator Model
Remote Set Regulator
Block Diagram of Analog Type Regulator
Current Output
Guard Input
Block Diagram of Raise/Lower Type Regulator
Raise/Lower Regulator Model
Data Plate
Model Number Breakdown
= Pneumatic Output = Mounting Arrangement
Page
Mounting
General
Two-Inch Pipe Mounting
In-Line Mounting
General Piping
Pressure Connections
Moisture in Lines
Regulator Assembly
Line Size
Internal Access
Venting
Body and Cover
Electrical Conduit Port
Safety Note
Page
Cradle Switches with Open Designation
Using Option Switches
Slide Switches with on Designation
Regulator Assembly Switch SW1 & SW2 Functions & Settings
Switch Functions
Analog Input Models
RAISE/LOWER Input Models
Incremental Signal
Continuous Signal
Input Filter
Switch SW1 1-5, Pulse Increments
Output Rate of Change
Guard Input
Static or Dynamic Guard Input
Guard Logic
Analog Failure Modes Fail Hold & Fail Zero
Switch SW2 2-5, Output Rate Of Change
FAIL-ZERO Mode
Page
Field Wiring
Terminal Identification For Raise/Lower Models
Terminal Identification For Analog Input Models
Analog Voltage Input with Guard
RAISE/LOWER Inputs with Guard
Analog Current Input 4-20 mA with Guard
Raise/Lower & Guard Inputs from Relay Contacts
Current Output to FSK Bi-State Transmitter
DC Power
Initial Checks
Operating Notes
Field Wiring CI-9110
Service
Troubleshooting Hints
Test Setup
Setting Output Limits
Procedure
General Principles
Calibration Precaution
Calibration Test Setup
Preliminary Calibration Check
Analog Test Setup
Feedback Zero & Span
Detailed Calibration for Analog Model
Current Output Span & Load
Pressure Output Check
Detailed Calibration for RAISE/LOWER Model
Raise/Lower Test Setup
CPU Board & Termination Board Reference Table
PCB Reference Drawings
Assembly, Analog Type CPU Board with Current Output
Assembly, Raise/Lower Type CPU Board with Current Output
RAISE/LOWER Input Model
Analog Input Model
Accuracy Analog Models
Analog Output
Accuracy RAISE/LOWER Models
Stepper Drive Mechanism
Instrument Enclosure
Pressure Regulator Assembly
Environmental
Range Factory Calibrated with
Humidity 10 to 95% over -20to +130 F -29to +55 Range
Parts Referenced in Figure
Model 9110 Main Parts
Remote Set Regulator Actuator Unit
Remote Set Regulator Actuator Unit Mounting Parts
Remote SET Regulator Basic Parts
Remote Set Regulator Assembly Basic Parts
Guidelines for System Grounding
Basic Ground Rod Installation
General Recommendations
Noise and Signal Errors
Grounding of Equipment Housing
Transients and Interference
Grounding of Transmitter
Types of Earth Grounds
AC Power Grounding System
Sandy Soil
Dry Soil
Rocky Soil
Following installation procedures apply
Several DPCs Mounted in Metal Cabinet with Power Supply
Grounding for DPCs and Power Supplies Single Metal Cabinet
Multiple DPC Cabinets Powered by Single Power Supply
Elements of a Facility Ground System
References
Multiple Clusters of DPC Cabinets Powered by Local Supplies