22
23
24
25
26
27
28
<
>
Troubleshooting
Install
Continuous Signal
Noise and Signal Errors
Field Wiring
Warranty
Internal Access
Test Setup
Regulator Assembly
Calibration Precaution
Page 24
Image 24
Page 23
Page 25
Page 24
Image 24
Page 23
Page 25
Contents
Remote Set Regulator Model 9110-00A
IMPORTANT! Read Instructions Before Starting
Warranty
Mail
Bristol Inc
Phone
Bristol Inc. Repair Authorization Form off-line completion
Training
Telephone Support Technical Questions
860 860 945-2213 FAX
Visit our Site on the World Wide Web Training Courses
Model 9110-00A Remote SET Regulator
Supplemental Instructions
Product Description
Theory of Operation
Analog Regulator Model
Remote Set Regulator
Block Diagram of Analog Type Regulator
Guard Input
Current Output
Block Diagram of Raise/Lower Type Regulator
Data Plate
Raise/Lower Regulator Model
Model Number Breakdown
= Pneumatic Output = Mounting Arrangement
Page
General
Mounting
Two-Inch Pipe Mounting
In-Line Mounting
Pressure Connections
General Piping
Regulator Assembly
Moisture in Lines
Internal Access
Line Size
Venting
Body and Cover
Safety Note
Electrical Conduit Port
Page
Using Option Switches
Cradle Switches with Open Designation
Slide Switches with on Designation
Switch Functions
Regulator Assembly Switch SW1 & SW2 Functions & Settings
Analog Input Models
RAISE/LOWER Input Models
Continuous Signal
Incremental Signal
Switch SW1 1-5, Pulse Increments
Input Filter
Guard Input
Output Rate of Change
Static or Dynamic Guard Input
Guard Logic
Switch SW2 2-5, Output Rate Of Change
Analog Failure Modes Fail Hold & Fail Zero
FAIL-ZERO Mode
Page
Field Wiring
Terminal Identification For Analog Input Models
Terminal Identification For Raise/Lower Models
Analog Voltage Input with Guard
Analog Current Input 4-20 mA with Guard
RAISE/LOWER Inputs with Guard
Raise/Lower & Guard Inputs from Relay Contacts
DC Power
Current Output to FSK Bi-State Transmitter
Operating Notes
Initial Checks
Field Wiring CI-9110
Service
Troubleshooting Hints
Setting Output Limits
Test Setup
Procedure
General Principles
Calibration Test Setup
Calibration Precaution
Analog Test Setup
Preliminary Calibration Check
Detailed Calibration for Analog Model
Feedback Zero & Span
Current Output Span & Load
Pressure Output Check
Raise/Lower Test Setup
Detailed Calibration for RAISE/LOWER Model
PCB Reference Drawings
CPU Board & Termination Board Reference Table
Assembly, Analog Type CPU Board with Current Output
Assembly, Raise/Lower Type CPU Board with Current Output
Analog Input Model
RAISE/LOWER Input Model
Analog Output
Accuracy Analog Models
Accuracy RAISE/LOWER Models
Stepper Drive Mechanism
Pressure Regulator Assembly
Instrument Enclosure
Environmental
Range Factory Calibrated with
Humidity 10 to 95% over -20to +130 F -29to +55 Range
Model 9110 Main Parts
Parts Referenced in Figure
Remote Set Regulator Actuator Unit
Remote Set Regulator Actuator Unit Mounting Parts
Remote Set Regulator Assembly Basic Parts
Remote SET Regulator Basic Parts
Guidelines for System Grounding
Basic Ground Rod Installation
Noise and Signal Errors
General Recommendations
Grounding of Equipment Housing
Transients and Interference
Grounding of Transmitter
Types of Earth Grounds
AC Power Grounding System
Dry Soil
Sandy Soil
Rocky Soil
Several DPCs Mounted in Metal Cabinet with Power Supply
Following installation procedures apply
Grounding for DPCs and Power Supplies Single Metal Cabinet
Multiple DPC Cabinets Powered by Single Power Supply
Elements of a Facility Ground System
Multiple Clusters of DPC Cabinets Powered by Local Supplies
References
Page
Remote Set Regulator Model 9110-00A
Top
Page
Image
Contents