Removing a Power Supply
6.With the power supply properly inserted into the opening, carefully slide the module until it connects to the backplane, as shown in Figure 2‐2 on page 2‐9. The module’s handle should be nearly flush with the back of the G‐Series switch. If significant resistance is encountered before the power supply is seated, remove and reinsert it. Do not force the module into place.
Figure 2-2 Installing a Power Supply Module (1200-watt module into PWR 2 slot shown)
1 Power supply | 2 Power supply handle | 3 Captive screws |
7.Secure the power supply to the chassis by tightening the captive screws.
8.If you are installing an additional power supply, repeat step 4 through step 7. If not, ensure that the unused power slot has a coverplate installed over it.
Removing a Power Supply
To remove a power supply, proceed as follows:
1.Attach an anti‐static wrist strap before handling the power supply module.
2.Unplug the associated power cord from the outlet.
3.Unplug the power cord from the AC inlet (associated with the power supply you are removing) at the back of the chassis.
4.Unscrew the captive screws to release the power supply from the chassis.
5.Remove the power supply by grasping the handle and pulling it straight out of the chassis.
6.Fasten a coverplate over the empty slot.
Caution: If you plan to operate the chassis with only one power supply, be sure to install the coverplate in place of the removed power supply to contain EMI radiation and ensure proper air circulation.
Precaución: Si desea trabajar sólo con una fuente de poder, no olvide colocar la tapa en el compartimiento de la fuente de poder que haya eliminado, para reducir la interferencia electromagnética y para asegurar una buena ventilación.
Enterasys