Appendix A: The Test Button

Factory Default Follow these steps to reset the AXIS 1440 to the factory default Settings settings.

1.Unplug the external power supply.

2.Press and hold down the test button while you plug the external power supply back in. Continue to hold down the test button until the network indicator begins to flash at one second intervals. (This should take at least 5 seconds.)

3.Release the test button and wait until the network indicator flashes at least five times.

4.Press and hold down the test button again for at least five seconds until the network indicator remains lit.

The AXIS 1440 is now reset to its factory default settings. Restart the AXIS 1440 by turning it off and then on again.

Note: All parameters except Node Address (NODE_ADDR) are reset. Use AXIS NetPilot or the internal web pages to change the node address. See Section 9 Management and Configuration.