Power Supply

Option slot power limits

Maximum Current

+5 Volts

+12 volts

-5 Volts and -12 Volts

 

 

 

 

For each slot

7 Amps

1.5 Amps

0.3 Amps

 

 

 

 

For all four slots

16 Amps

3 Amps

0.3 Amps

 

 

 

 

Environmental

Requirements

 

 

 

 

 

 

 

 

 

Condition

Operating range

 

Non-operating

Storage range

 

 

 

 

range

 

 

 

 

 

 

 

 

Temperature

41° t0 90° F

 

- 4°to140°F

-4° to 140° F

 

 

(5° to 32° C)

 

(-20° to 60° C)

(-20° to 60° C)

 

 

 

 

 

 

 

Humidity

20% to 90%

 

10% to 90%

10% to 90%

 

(non-

 

 

 

 

 

condensing)

 

 

 

 

 

 

 

 

 

 

 

Altitude

-330 to 9,900 ft

 

-330 to 39,600 ft

-330 to 39,600 ft

 

 

(-100 to 3,000 m)

 

(-100 to 12,000 m)

(-100 to 12,000 m)

 

 

 

 

 

 

 

Maximum

68° F

 

104°F

134° F

 

wet bulb

(20° C)

 

(40° C)

(57° C)

 

 

 

 

 

 

 

Acoustical

37.5 dB(A)

 

N/A

N/A

 

noise

 

 

 

 

 

 

 

 

 

 

A-4 Specifications