If a coax host Is not available and basic setup selections need to be changed, the interface has the option of a push button setup as defined in Appendix B. This option enables the basic interface features and RPQ options to be selected.
RESTORING FACTORY DEFAULT CONFIGURATION
The factory default configuration selections can be restored to the NV memory of the interface by either sending a Host Download Command ‘98,0’or by turning on the printer when the coax cable is disconnected and performing the following steps (waft for printer to be READY):
1.Press and hold the bottom (PA2) button for more than two seconds and then release; the red and green LED begin to blink alternately.
2.Press and release the top (PA1) button; only the green LED blinks.
3.Press and release the bottom (PA2) button; the red LED blinks twice.
4.Sequence is complete. Factory defaults are restored to the NV memory of the interface. Turn the printer off and then back on.
PRINTER FEATURE ACCESS METHODS
This interface features three methods for accessing the special features of Epson printers not normally available in the IBM printers being emulated:
Custom User Strings
SCS Mode Transparent Data
Each of these methods is described below.
1. COMMAND-PASS-THRU
DESCRIPTION
The