Data transfer is carried out by observing the ACKNLG or BUSY signals. Data

transfer to the printer occurs only after receipt of the ACKNLG signal or when the BUSY signal is LOW.

TIMING

DATA IN- /\\/

 

 

 

.5usec

.5usec

.5usec

 

 

 

 

 

 

m i n .

m i n .

m i n .

 

 

 

S T R O B E

 

-II

 

 

 

 

 

 

 

 

 

 

 

 

 

BUSY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approx.

A p p r o x .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7usec min

5usec.

 

ACKNLG

 

 

 

 

II-

 

 

I

 

 

 

 

 

 

 

 

 

 

Data must be present a minimum of 0.5 microseconds before and after a minimum 0.5 microsecond STROBE pulse. BUSY goes high before the end of the STROBE signal and remains high until the end of an ACKNLG pulse of minimum 4 microseconds.

EPSON HP LASERJET EMULATION

Most Epson laser printers have an option to emulate the Hewlett Packard LaserJet printer. Check your user’s guide to determine if your printer has this option, which can be selected from the front panel of the printer. Be sure to save the HP option selection into the printer's default settings so the HP option is always loaded at power-on. The HP option provides increased capability including easy font selection and portrait and landscape printing.