COMMAND 17: VALID FF FOLLOWED BY DATA
Sets the printer in accordance with the RPQ installed in the control unit
VALUE DESCRIPTION
* 0 Second print position of first line on next form
1 First print position (PP) of first line on next form
NOTES: For the Value 1 selection, the RPQ would be:
IBM 3268 RPQ SC9503
IBM 3287 RPQ N/A
IBM 4214 OPT 16=2
Available only in
EXAMPLE: &%Z17,1 Performs first PP of first line on next form as the next
PPwhen a valid FF (positioned anywhere but the end of an IBM print buffer) is received.
COMMAND 18: VALID FF AT END OF PRINT BUFFER
Sets the printer in accordance with the RPQ installed in the control unit
VALUE DESCRIPTION
0First PP of second line on next form
*1 First PP of first line on next form
NOTES: To use this function, the RPQ should be:
IBM 3268 RPQ SC9504
IBM 3287 RPQ SC3749
IBM 4214 OPT 17=2
Available only in
EXAMPLE: &%Z18,1 Performs first PP of first line on next form as the next
PPwhen a valid FF is received at the end of an IBM print buffer.