COMMAND 17: VALID FF FOLLOWED BY DATA

Sets the printer in accordance with the RPQ installed in the control unit

VALUE DESCRIPTION

* 0 Second print position of first line on next form

1 First print position (PP) of first line on next form

NOTES: For the Value 1 selection, the RPQ would be:

IBM 3268 RPQ SC9503

IBM 3287 RPQ N/A

IBM 4214 OPT 16=2

Available only in non-SCS operation

EXAMPLE: &%Z17,1 Performs first PP of first line on next form as the next

PPwhen a valid FF (positioned anywhere but the end of an IBM print buffer) is received.

COMMAND 18: VALID FF AT END OF PRINT BUFFER

Sets the printer in accordance with the RPQ installed in the control unit

VALUE DESCRIPTION

0First PP of second line on next form

*1 First PP of first line on next form

NOTES: To use this function, the RPQ should be:

IBM 3268 RPQ SC9504

IBM 3287 RPQ SC3749

IBM 4214 OPT 17=2

Available only in non-SCS operation

EXAMPLE: &%Z18,1 Performs first PP of first line on next form as the next

PPwhen a valid FF is received at the end of an IBM print buffer.

A-10