COMMAND 19: FF VALID LOCATION

Sets the printer in accordance with the RPQ installed in the control unit

VALUE DESCRIPTION

* 0 FF is valid only at the first print position or at position MPP+1.

1 FF is valid anywhere it occurs.

NOTES: To use this function, the RPQ should be:

IBM 3268 RPQ SC9506

IBM 3287 RPQ SC3739

IBM 4214 OPT 19=1

Available only in non-SCS operation.

EXAMPLE: &%Z19,1 Makes FF valid anywhere it occurs

COMMAND 20: AUTOMATIC FUNCTION AT END OF JOB

Sets the printer in accordance with the RPQ installed in the control unit.

VALUE DESCRIPTION

*0

1

NL is automatically executed after the buffer is completed (unless an FF, NL, or CR was last in the buffer).

FFis automatically executed after the print buffer is completed (unless an FF was last in the buffer).

NOTES: To use this function, the RPQ should be:

IBM 3268 RPQ SC9507

IBM 3287 RPQ SC3740

IBM 4214 OPT 20=2

Available only in non-SCS operation

Do not press the form feed or line feed buttons on the front of the printer. This will cause the host and printer to lose synchronization of paper position. This command reduces the need to advance the paper.

EXAMPLE: &%Z20,1 Sets the printer to issue an FF automatically at the end of the print buffer.