COMMAND 41: COMMAND ID CHARACTER

Specifies the character which can be used for the command identifier (in place of "Z" which follows the ‘Lead In’characters.

VALUE DESCRIPTION

*5A

Makes Z the command character.

ZZZZ is the ASCII HEX value of the command ID character.

NOTE: The character selected must not be 0 through 9 or A through F (valid hex values), or L, P, U.

EXAMPLE: &%Z41,59 Specifies ‘Y’as the alternate command ID character

COMMAND 42: START AND STOP BUFFER HEX DUMP

Upon receipt of a start command, the coax interface, starting with the next buffer received, sends all host data directly to the printer as hexadecimal printing until a stop command is received or the printer is powered off.

VALUE DESCRIPTION

*0 No Action Taken

1 Start Buffer Hex Dump

2 Stop Buffer Hex Dump

NOTES: This is an alternative to pressing both push buttons on the interface card and holding them for more than 2 seconds to activate Buffer Hex Dump.

This command enables the user to print only the section of the document that is in question in Buffer Hex Dump Format. But, hex printing starts with the buffer following the start command and stops with the buffer following the stop command.

EXAMPLES: &%Z42,1 Starts Buffer Hex Dump Printing &%Z42,2 Stops Buffer Hex Dump Printing

A-17