COMMAND 34: INTERVENTION REQUIRED (IR) TIME OUT
Sets the time interval before an intervention required signal is sent to the host after a printer error occurs.
VALUE DESCRIPTION
000 Never send an IR
001Send IR after the VALUE times 5 seconds after printer error
to occurs.
*120 Default, send IR after ten minutes. EXAMPLE: &%Z34,036 Sets IR time interval to 3 minutes
COMMAND 35: PROGRAM ATTENTION (PA) RESPONSE
The IBM host software can send a program attention (PA) request to the printer, causing the printer to stop printing until a PA1 or PA2 response from the printer is sent to the host software. The interface can be set to either automatically return a PA1 response upon receiving a PA request or stop and wait (with red LED on) until the operator presses one of the two push buttons on the interface card.
VALUE DESCRIPTION
*0 Printer stops and waits for operator to press a PA1 or PA2 push button before sending the PA response to the host.
1Interface automatically responds with a PA1 if a PA request is received from the host.
NOTE: This can be used to enable an operator to install special forms, colored paper, legal paper, etc. in the printer before the PA push button is pressed.