4.5ALARM & EVENT SETTING
Figure 4-10 is a screenshot of the ALARM & EVENT SETTING MENU. This menu will guide you through alarm and event setup.
Figure 4-10 Alarm & Event Menu - Alarm
4.5.1Alarm
Alarm: Select the alarm input trigger connection number from 1 to 4 (or 8 – one trigger per camera input).
Enable: Check box to enable response to that alarm trigger.
Log: Check box to record these alarm events in the log.
Buzzer: Check this box to enable the buzzer when an alarm occurs.
Main Monitor: Main monitor display options when a motion occurs. No change: No change on the main monitor display.
Full screen: A full screen of the active camera will display on main monitor. Record: Select which camera(s) will start recording in response to this alarm event.
Email Notify: Check box to enable email notification when an alarm occurs. Email operation requires that valid email settings have been entered in the Network Setting/Email setup screen. (See Section 4.6.2 Email for more information.)
Input Type: This field is to change the type of alarm trigger. N.O.: Normal Open contact.
N.C.: Normal Closed contact.
48