EverFocus ECOR 264-8/4 F2 RS-485KEYBOARD / PTZ Installation, General RS-485 bus installation

Models: ECOR 264-8/4 F2 ECOR 264-8/4 D2

1 124
Download 124 pages 33.61 Kb
Page 16
Image 16

1.8RS-485KEYBOARD / PTZ INSTALLATION

All functions can be remote-controlled by the EKB-500 universal keyboard. Using the EEPbus protocol, digital video recorders, keyboards and speed domes can be installed on one single RS-485 bus. One system can comprise up to 8 keyboards.

1.8.1General RS-485 bus installation

The EKB-500 keyboard uses a RS-485 simplex wiring; the signal is transferred via a single twisted pair line. CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal applications. A shielded cable should be used if the installed cables are expected to be highly susceptible to interference. The number of devices installed in one bus is limited to 32, and the maximum cable length is 3,900 feet. Both of these can be expanded using a signal distributor EverFocus Model EDA997A (see below).

Both the first and the last device in series should be terminated with 120 Ohm resistance in order to minimize line reflections.

RS-485 bus serial wiring

Cable length from box to device („Stubs“) has to be limited to 2m using connector boxes.

RS-485 bus serial wiring with connector boxes and connection cable

Direct RS-485 bus star wiring is not supported unless using an EverFocus Model EDA997A (see below).

Improper RS-485 bus star wiring

An EDA997A RS-485 signal distributor may be used to use a star wiring configuration.

Star wiring with RS-485 signal distributor

10

Page 16
Image 16
EverFocus ECOR 264-8/4 F2, ECOR 264-8/4 D2 user manual RS-485KEYBOARD / PTZ Installation, General RS-485 bus installation