EverFocus ECOR 264-8/4 D2, ECOR 264-8/4 F2 user manual Alarm & Event Menu Event Power Loss

Models: ECOR 264-8/4 F2 ECOR 264-8/4 D2

1 124
Download 124 pages 33.61 Kb
Page 61
Image 61

Power Loss:

Figure 4-16 Alarm & Event Menu – Event – Power Loss

Log: Log is permanently checked for this feature. Power Loss events are always recorded by the DVR.

Email Notify: Check box to enable email notification when power has been restored. Email operation requires that valid email settings have been entered in the Network Setting/Email setup screen.

Network Alarm: Check box to send out a network alarm to client PC when power has been restored. (requires PowerCon software and setting up Alarm Server in Network Setup menu)

NOTE: As alarms and emails cannot be transmitted without power, the log entry is made when power is restored, and any notifications cannot be made until that time.