Appendix A • RS-232 Programmer’s Guide

Request System Configuration - CMD12 (3Ch)4

Request the System 4xi Configuration.

Format:

ESC, CMD12, EOT

Response:

ESC, CMD12, ERC, LD Sync, RGB Delay, Aud Mute, Status 1, LDxi Misc, reserved, EOT

Where: ESC, CMD12 = 1Bh, 3Ch

LD Sync

81h = Composite Sync with no serration pulses

 

82h

= Sync negative (horizontal & vertical)

 

83h

= Composite Sync with serration pulses

 

84h

= 6Sync positive (horizontal & vertical)

 

85h

= 6Sync positive horizontal, negative vertical

 

86h

= 6Sync negative horizontal, positive vertical

RGB Delay

80h - 8Ah = RGB Delay in 0.5 second steps

 

 

(values range from 0 to 5 seconds)

Aud Mute

80h = Audio is not Muted

 

81h

= Audio is Muted

Status 1

80h - 83h (See table below.)

 

 

 

Bit #

7·6·5·4·3·2

1

0

Function:

 

Sys Power

Model

Power is Off

1·0·0·0·0·0

0

x

Power is On

1·0·0·0·0·0

1

x

Sys 4C

 

1·0·0·0·0·0

x

1

Sys 4LD, 4LDex, 4LQex

1·0·0·0·0·1

x

0

Sys 4LDxi, 4LQxi

1·0·0·0·0·1

x

0

LDxi Misc6

80h

- AAh (See table.)

 

 

 

 

 

Bit #s

76

54

32

10

Function:

 

Demo

Freeze VGA

Demo mode On

10

01

xx

xx

Demo mode Off

10

10

xx

xx

Freeze On

 

10

xx

01

xx

Freeze Off

 

10

xx

10

xx

Not VGA resolution

10

xx

xx

01

Force VGA resolution

10

xx

xx

10

 

 

 

 

 

 

 

reserved

80h

= reserved

 

 

 

 

EOT

04h

= End Of transmission

 

 

4.This command is only available in System 4xi units with the following firmware revision levels, or higher: System 4LDxi – revision 3.0 System 4LQxi – revision 4.0

6.Only available on System 4LDxi and System 4LQxi

Example: (Request System Configuration) 1Bh, 3Ch, 04h

Response:

1Bh, 3Ch, 80h, 83h, 80h, 81h, 82h, A9h, 80h, 04h

Says: LD Sync = Composite with serration pulses, RGB Delay = none, Audio is Muted, Model = System 4LDxi , 4LQxi , Switcher Power = On, Demo Mode = Off, Freeze = Off and VGA Resolution is not forced.

A-15

Extron • System 4xi Switcher Series • User’s Manual

Page 66
Image 66
Extron electronic 4LDXI, 4LQXI manual Request System Configuration CMD12 3Ch4, ESC, CMD12, EOT