Using the command/response tables

The command/response tables on the next page list valid command ASCII codes, the scaler’s responses to the host, and a description of the command’s function or the results of executing the command. Upper and lower case characters may be used interchangeably in the command field.

The ASCII to HEX conversion table at left is for use with the command/response tables.

ASCII to HEX Conversion Table

ASCII to Hex conversion table

The command/response tables use symbols (defined below) to represent variables.

Symbol definitions

= CR/LF (carriage return/line feed) (hex 0D 0A)

= Space

Esc

=

Escape key

X1

=

Specific input number (0 through 4)

 

 

0

= no input

 

 

1

= input 1, 2 = input 2, and so forth

X2

=

0 = off, 1 = on

X4

=

Video signal type (1 through 7)

 

 

1 = composite video

 

 

2

= YC

 

 

3

= YUV

 

 

4 = RGB

 

 

5

= RGBS

 

 

6

= RGBcvS

 

 

7

= SDI (serial digital interface)

X5

=

Input (1 to 4)

X8

=

Controller firmware version (listed to

 

 

two decimal places e.g.: x.xx)

 

=

Picture adjustment range (0 through 255)

X10

X11 = Scaler resolution

1= 640x480

2= 800x600

3= 848x480

4= 852x480

5= 1024x768

6= 1280x768

7= 1280x1024

8= 1360x765

9= 1365x1024

10= 480p

11= 720p

12= 1080p

13= 1080i

14= 1400x1050

15= 576p

X12 = Detected input signal standard (0 through 4)

0 = none

1 = NTSC 3.58

2 = PAL

3 = NTSC 4.43

4 = SECAM

= not applicable (occurs when the input is set for RGB, YUV, or progressive YUV)

X13 = Detail level (0 through 63)

X14 = Adjustment range (0 through 127)

X16 = Executive mode status (0 through 2)

0 = disabled (executive mode off, normal mode on)

1 = enabled, image adjustments are locked

X17 = Blanking adjustment range (0 through 127 lines)

X19 = Input configuration preset (1 through 3)

X20 = Scaler refresh rate

1= 50 Hz

2= 56 Hz (1280x768 only)

3= 60 Hz

4= 75 Hz

5= AFL* (50 Hz for PAL or 59.94 Hz for NTSC)

6= True rate (72 Hz for NTSC or 100 Hz for PAL)

*NOTE: Lock or AFL is Accu-RATE Frame Lock

DVS 204 • Serial Communication

3-3

Page 35
Image 35
Extron electronic DVS 204 D 12V, DVS 204 12V manual Using the command/response tables, Symbol definitions