Extron electronic DVS 204 D Command/response table for special function SIS commands, values

Models: DVS 204 D DVS 204 12V DVS 204 DVS 204 D 12V

1 52
Download 52 pages 14.46 Kb
Page 39
Image 39
Command/response table for special function SIS commands
filter.
1 = on (default) enable the reconstruction
0 = off, Example:
setup.
0 = off (default), 1 = on
Example: enable auto switch mode.
Example:
(default) (RGB & sync output)
0 = off
1 = on (blue video & sync output only) blue & sync output for
and additional descriptions
0 = off,
1 = on,
Example: enable enhanced mode.
0 = RGB
1 = YUV
2 = RGsB (sync on green, SOG) Example: RGB sync output
0 = H-/V- (default)
1 = H-/V+
2 = H+/V-
3 = H+/V+
Example: H-/V+ sync polarity

The syntax for setting a special function is X? * X! # where X? is the function number and X! is the value. To view a function’s setting, use X? # where X? is the function number. In the following table the values of the X? variable are different for each command/function. These values are given in the rightmost column.

Command/response table for special function SIS commands

Command

ASCII Command Response

 

(host to scaler)

(scaler to host)

X!

values

Enhanced mode

Enhanced mode

12 *

X!

#Enh

X!

Example:

12*1#
Enh1

Scaler settings

Output signal

6 *

X!

Example:

6*0#

Scaler output polarity

7 *

 

X!

Example:

7*1#

#Syn X! ASCII Command Responsevalues

Syn0Enhanced mode

#Pol X! 12*1#Enh1

Pol1Scaler settings

Blue screen

Blue screen (blue & sync output only)

8*

X!

#Blu

X!

Example:

8*1#
Blu1

Auto switch

Auto switch mode

10*

X!

Example:

10*1#

#Aut X! Blue screen8*1# Aut1 Blu1

Reconstruction filter

Reconstruction filter

11*

X!

Example:

11*1#

#Fil X! Auto switchReconstruction filter Fil1PAL Film mode (2:2 pulldown detection)

PAL Film mode (2:2 pulldown detection)

PAL film mode detection

18*

X!

#

Flm

X!

Example:

18*1#

 

Flm1

0 = off (default), 1 = on Example: enable PAL film mode.

detection

H Format (sync output format for “H” connector)

RGBS H format

15*

X!

Example:15*1#

#

HFm

X!

0 = H – horizontal sync (default)

 

 

 

1 = HV – composite sync

 

HFm1

Example: Output composite sync

 

 

 

on “H” connector. See “H Format”

 

 

 

and “RGB pass-through” sections in

 

 

 

chapter two for a complete

 

 

 

description of this function.

RGB delay times

RGB delay

3 *

X!

Example:3*7#

#

RGB

X!

0

= 0.0 seconds (default),

 

 

 

1

= 0.5 seconds, 2 = 1.0

 

 

 

seconds, ... in ½ second steps

 

 

 

up to 10 = 5.0 seconds

 

RGB07

Example: 3.5 second RGB delay

DVS 204 • Serial Communication

3-7

Page 39
Image 39
Extron electronic DVS 204 D Command/response table for special function SIS commands, ASCII Command Response, values, Enh1