Installation and Operation, cont’d
3.Rotate the Adjust horizontal knob () or Adjust vertical knob () to select a level from the following adjustment ranges:
The Adjust knobs have no mechanical limits to their rotation.
•Color and Tint (Col/Tnt): 0 to 255 (see note below)
•Brightness and Contrast (Brt/Cont): 0 to 255
•Centering (Center): 0 to 255
•Sizing (Size)
Rotating the horizontal Adjustment knob () clockwise or counterclockwise will increase or decrease, respectively, the horizontal sizing. Rotating the vertical Adjustment knob () clockwise or counterclockwise will increase or decrease, respectively, the vertical sizing. The visual indicator on the LCD will stop moving when the upper or lower sizing limit has been reached.
The scaler will
4.Repeat steps 2 and 3 for each image adjustment to be made for that input.
The LCD display will indicate that a Tint adjustment is not available (N/A) for Input 2 (component) or Input 4 (RGB, RGBS, RGBcvS).
Input Reset
Each input of the DVS 204 scaler can be reset to its default centering and sizing values by holding down the specific input button until the Input # Reset message is displayed on the LCD screen.
System Reset
The DVS 204 can be reset to all of its default values by holding down the Input 1 button while simultaneously plugging in the power cord. The System Reset message will be displayed on the LCD screen.