Serial Communication, cont’d

Command/response table for SIS commands (continued)

 

Command

ASCII Command

Response

Additional description

 

 

(host to scaler)

(scaler to host)

 

 

Freeze

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

1F

Frz1

Output a “frozen” video

 

 

 

 

 

 

image.

 

Disable

0F

Frz0

Turn off freeze (output

 

 

 

 

 

 

motion).

 

 

 

 

 

 

 

 

View the freeze status

F

Frz X2

Show the freeze status.

 

Example:

F

Frz0

 

 

Front panel security lockout (Executive mode)

 

 

 

 

 

 

 

 

 

 

 

 

Disable

0X

Exe0

Adjustments & selections can

 

 

 

 

 

 

be made from the front panel.

 

Enable (lock image adjustments)

1X

Exe1

Lock front panel adjustments;

 

 

 

 

 

 

adjust image via RS-232 only.

 

View the executive mode status

X

Exe

X16

 

Show executive mode status.

 

Example:

X

Exe0

 

Firmware version, part number & information requests

Query firmware version number

Q

Ver

X8

Show the controller firmware version.

Request part number

N

N60-442-0_

 

 

 

Show the scaler’s part #.

 

 

 

 

 

 

 

Request general info.

I

(See below)

 

 

 

Show the scaler’s status.

 

 

C X1 •Typ X4 •Std

X12

•Pre

X19

•Sdi X1

Zap (reset to default settings)

Zap image adjustments/controls

Zap all DVS 204 settings/memories

Esc

Esc

zI

ZapI

Reset the image adjustments

 

 

to factory settings.

zXXX

ZapXXX

Reset everything: all settings

 

 

and adjustments to the factory

 

 

default.

3-6 DVS 204 • Serial Communication

Page 38