DISPLAY SET-5

DISPLAY SET SETTINGS

Example 2: To set the automatic switching period for the main monitor.

Set cameras 1 to 8 to 2-second automatic switching displays.

Set camera 9 to 16 to 3-second automatic switching displays.

Note: The automatic switching display period for spot monitors can be set in the same way (when the setting conditions for each camera are the same as for the main monitor).

1

 

Use the cursor button to select

 

SEQUENCE “1S”.

 

 

(DISPLAY SET)

 

 

 

TITLE

DOWN

¤

 

 

MULTI SCREEN

NORMAL

 

 

SEQUENCE

1 S

 

 

 

MASK

OFF

 

 

 

MAIN†SPOT1

OFF

 

 

 

DIGITAL CONNECTION OFF

 

 

 

COLOR LEVEL

AUTO

 

 

 

(*:NEXT)

 

 

2

 

Use the setting button (–) to select

 

“INDIV.”, and then press the NEXT

NEXT

button.

 

 

 

 

 

 

 

 

The SEQUENCE SET screen will be

 

 

displayed.

 

 

 

 

(DISPLAY SET)

 

 

 

TITLE

DOWN

¤

 

 

MULTI SCREEN

NORMAL

 

 

SEQUENCE

INDIV.*

 

 

MASK

OFF

 

 

 

MAIN†SPOT1

OFF

 

 

 

DIGITAL CONNECTION OFF

 

 

 

COLOR LEVEL

AUTO

 

 

 

(*:NEXT)

 

 

3

 

Use the cursor button to select the

MAIN MONITOR “1S” setting, and

 

then press the setting buttons (–) to

 

 

 

 

change the setting to “INDIV.”.

 

 

INDIV. INTERVAL appears at the bottom

 

 

of the screen.

 

 

 

 

(SEQUENCE SET)

 

 

 

MAIN MONITOR

INDIV.¤

 

 

SPOT MONITOR-1

1 S

¤

 

 

SPOT MONITOR-2

1 S

¤

 

 

SPOT MONITOR-3

1 S

¤

 

 

SPOT MONITOR-4

1 S

¤

 

 

QUAD

1 S

 

 

 

INDIV. INTERVAL

 

*

 

 

(*:NEXT)

 

 

4

 

Use the cursor button to select

NEXT

“INDIV. INTERVAL” and then press

 

 

 

the NEXT button.

 

 

The INDIVIDUAL INTERVAL screen will be

 

 

displayed.

 

 

 

 

(SEQUENCE SET)

 

 

 

MAIN MONITOR

INDIV.¤

 

 

SPOT MONITOR-1

1 S

¤

 

 

SPOT MONITOR-2

1 S

¤

 

 

SPOT MONITOR-3

1 S

¤

 

 

SPOT MONITOR-4

1 S

¤

 

 

QUAD

1 S

 

 

 

INDIV. INTERVAL

 

*

 

 

(*:NEXT)

 

 

5

 

UseKtheKcursorKbuttonKtoKselect

+

“01:1S”, and then press the setting

buttons to change the setting to

 

 

 

 

“2S”.

Automatic switching display at the specified switching interval is enabled when you have entered a switching period for each camera.

With the same procedure:

Set 02 to 08 to 2 S.

Move the cursor to the right and set 09 to 16 to 3 S.

(INDIVIDUAL INTERVAL)

(INDIVIDUAL INTERVAL)

IN

 

IN

 

IN

 

IN

 

01:

1 S

09: 1 S

01: 2 S

09: 3 S

02:

1 S

10: 1 S

02: 2 S

10: 3 S

03: 1 S

11: 1 S

03: 2 S

11: 3 S

04: 1 S

12: 1 S

04: 2 S

12: 3 S

05: 1 S

13: 1 S

05: 2 S

13: 3 S

06: 1

S

14: 1

S

06: 2

S

14: 3

S

07: 1

S

15: 1

S

07: 2

S

15: 3

S

08: 1

S

16: 1

S

08: 2

S

16: 3

S

6

Press the BACK button.

The setting will then be completed.

BACK MENU

 

Press the BACK button once more to

 

return to the MAIN MENU screen.

Press the MENU button.

The display will return to the camera image display screen.

If the SEQUENCE button is then pressed, the screen images will start switching automatically according to the settings that have been made.

– 44 –