INTERFACE SPECIFICATIONS

RS-232C9-pin connector specifications

1 2 3 4 5

6 7 8 9

Pin No.

Signal

Operation

Signal direction

 

1

 

 

2

RXD

Receive data

Computer → Μυλτιπλεξερ

 

 

 

 

 

3

ΤΞΔ

Τρανσ∝ιτ δατα

Μυλτιπλεξ→Χο∝πυτερ

4

 

5

GND

Ground

 

6

 

7

RTS

Request to send

Multiplexer → Χο∝πυτερ

8

 

9

 

Data format

Mode

Asynchronous

Character length

8 bits

Data transmit speed

2400, 4800, 9600, 19200 bps

Parity

None

Stop bit

1

Communication protocol

Communication is carried out in units of 1 byte. After the computer transmits one byte of data, it waits for a response from the multiplexer, and then transmits the next byte of data.

To start sending commands, an ON (F6) command is sent. The multiplexer will continue to receive commands until an OFF (F7) command is sent to stop. The multiplexer sends an ACK (OA) each time it receives a command.

See Table 4 - Command Table on page 79.

RS-485RJ-11 connector specifications

 

 

 

 

 

 

 

 

 

 

Pin No.

Pin A signals

Pin B signals

1 2 3 4 5 6

 

 

1

Spare

Spare

 

 

 

 

 

 

 

 

 

 

2

Spare

Spare

 

 

 

 

 

 

 

 

 

 

3

Signal B

Signal A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Signal A

Signal B

 

 

 

 

 

 

 

 

 

 

5

Spare

Spare

 

 

 

 

 

 

 

 

 

 

6

Spare

Spare

Data format

Mode

Asynchronous

Character length

8 bits

Data transmit speed

2400, 4800, 9600, 19200 bps

Parity

None

Stop bit

1

Communication protocol

A proprietary Sanyo protocol (SSP: Security Serial Protocol) is used. It is recommended that a special controller be used. Contact the place of purchase for further details on obtaining a special controller.