CONTROL SET SETTINGS

 

(MAIN MENU)

 

(CONTROL SET)

 

 

•3Set3a3data3transfer3rate3for3serial3communication.

1

LANGUAGE

*

DATA SPEED

19200

 

 

•3Set3whether3alarm3information3will3be3sent3or3not.

2

CLOCK SET

*

ALARM SEND

ON

 

 

•3Set3whether3RS-4853or3RS-232C3will3be3used3for3

 

 

3

DISPLAY SET

*

RS232C/RS485

RS232C

 

 

 

 

serial3communication.

4

VCR SET

*

 

 

 

 

5

ALARM SET

*

 

 

 

 

 

6

SECURITY SET

*

CAMERA CONTROL

SANYO *

 

 

 

 

 

 

7

CONTROL SET

*

 

 

 

 

Make3dome-type3camera3settings3to3enable3power3

8

ALARM DATA

*

 

 

 

 

 

(*:NEXT)

 

 

 

 

 

and3signal3control3with3a3RS-4853dedicated3coaxial3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable.

The following settings must be made if using the RS-232C connector or the RS-485 connector for serial communication between a computer or a system controller and the multiplexer.

CONTROL3SET3settings

Settings for serial communication between the computer and system controller using RS-232C connectors and RS-485 connectors.

1

 

Press the MENU button.

 

The MAIN MENU screen will be displayed.

MENU

 

 

 

 

 

 

 

(MAIN MENU)

 

 

1

LANGUAGE

¤

 

 

2

CLOCK SET

¤

 

 

3

DISPLAY SET

¤

 

 

4

VCR SET

¤

 

 

5

ALARM SET

¤

 

 

6

SECURITY SET

¤

 

 

7

CONTROL SET

¤

 

 

8

ALARM DATA

¤

 

 

 

(*:NEXT)

 

2

 

Use the cursor button to select

 

“CONTROL SET” and then press

NEXT

the NEXT button.

 

 

 

 

The CONTROL SET screen will be

 

 

displayed.

 

 

 

 

(CONTROL SET)

 

 

 

DATA SPEED

19200

 

 

 

ALARM SEND

ON

 

 

 

RS232C/RS485

RS232C

3

 

Use the cursor button to select

9

RS232C/RS485 “RS232C”, and then

 

 

 

4

+

5

– 9

Use3the3cursor3button3to3select

DATA3SPEED3“19200”, and then press the setting buttons to set the communication speed.

This sets the data communication speed for serial communication.

(CONTROL SET)

DATA SPEED

19200

 

ALARM SEND

 

 

ON

RS232C/RS485

RS232C

CAMERA CONTROL

SANYO *

2400,34800,39600,319200

Use the cursor button to select

ALARM SEND “ON”, and then press the setting buttons to select the alarm data.

(CONTROL SET)

DATA SPEED

19200

ALARM SEND

ON

RS232C/RS485

RS232C

CAMERA CONTROL

SANYO *

press the setting buttons to select

“RS232C” or “RS485”

(CONTROL SET)

DATA SPEED

19200

 

ALARM SEND

ON

RS232C/RS485

RS232C

 

Display examples:

Ωηεν ΡΣ−232Χ ισ σελεχτεδ

Display examples:

ΟΦΦ:Alarm data is not transmitted.

ΟΝ:Alarm data is transmitted.

6 Press the MENU button.

This completes the settings.

Use a commercially available RS-232C cable for the connection between the RS-232C connectors of this unit and a personal computer.

Ωηεν ΡΣ−485 ισ σελεχτεδ

Use a modular cable or a twisted-pair cable for the connections between the RS-485 control connectors of this unit, the system controller and the digital video recorder.

– 72 –

English