Installing a Redundant Power Supply

Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide

Installing a Redundant Power Supply

About the RPS2-EIF Redundant Power Supply

Overview

Foundry Network’s External Redundant Power Supply (RPS2-EIF) can supply a maximum of 150 Watts of output power per port, a total of 600 Watts of backup power to four FasrIron devices in the event of an AC loss or failure of an internal power supply.

The system operates as a backup to a switch's internal power supply. If an internal power supply fails, the RPS will support the full load of the switch without affecting network operation.

The following devices are supported by the FastIron RPS2-EIF: Foundry FastIron LS624 and FastIron LS648.

Features and Benefits

Supports four FastIron devices with 12V DC output

Status LEDs located on the front panel

AC line cord can draw power from a different supply circuit

DC line cord provides backup power to the attached device

Thermal overload protection prevents the RPS from overheating if a thermal overload occurs.

Over-voltage protection shuts down an output channel if the voltage exceeds a preset threshold.

Over-current protection shuts down the RPS if the output load exceeds a preset threshold.

Short-circuit protection prevents the RPS from being damaged from a short circuit on any output channel.

The power supply will operate under a no-load condition.

Front and Rear Panels

Four power indicators and one fan indicator are located on the RPS’s front panel. The AC supply and DC backup receptacles are located on the RPS’s rear panel.

Figure 3.4 Front and rear panels

 

 

 

 

Port and System Status Indicators

 

 

 

 

Link

 

 

 

 

 

 

 

 

Activity

 

 

 

 

 

 

 

 

1

2

3

4

Fan Thermal Power

 

 

 

 

 

 

 

 

100-240V, 50-60Hz 14A

BPS 4

BPS 3

 

BPS 2

BPS 1

 

 

 

 

Redundant Power Sockets 4~3

Fans

Redundant Power Sockets 2~1

 

 

Power Socket

 

 

FastIron RPS2-EIF

 

 

 

 

 

Package Contents

Redundant Power Supply Unit (RPS2-EIF)

One AC Supply Power Cord — US, Continental Europe or UK

Four DC Backup Power Cords with IEC connectors on both ends (length 152 cm each)

Rack Mounting Kit containing brackets and screws

Adhesive feet

3 - 8

© 2007 Foundry Networks, Inc.

September 2007

Page 24
Image 24
Foundry Networks LS 624, LS 648 Installing a Redundant Power Supply, About the RPS2-EIF Redundant Power Supply, Overview